banner
Our main products are electrophoresis cell, electrophoresis power supply, blue LED transilluminator, UV transilluminator, and gel imaging & analysis system.

Accessory for DYCP-31DN

  • DYCP-31DN Gel Casting Device

    DYCP-31DN Gel Casting Device

    Gel Casting Device

    Cat. No.: 143-3146

    This gel casting device is for DYCP-31DN system.

    Gel electrophoresis can be conducted in either a horizontal or vertical orientation. Horizontal gels are typically composed of an agarose matrix. Pore sizes of these gels depend on the concentration of chemical components: agarose gel pores (100 to 500 nm diameter) are larger and less uniform compared to that of acrylamide gelpores (10 to 200 nm in diameter). Comparatively, DNA and RNA molecules are larger than a linear strand of protein, which are often denatured prior to, or during this process, making them easier to analyze. Thus, DNA and RNA molecules are more often run on agarose gels (horizontally).Our DYCP-31DN system is a horizontal electrophoresis system. This molded gel casting device can make 4 different sizes of gels by different gel trays.

  • DYCP-31DN Comb 18/8 wells (1.5mm)

    DYCP-31DN Comb 18/8 wells (1.5mm)

    Comb 18/8 wells (1.5mm)

    Cat. No.: 141-3142

    1.5mm thickness, with 18/8 wells, for use with DYCP-31DN system.

  • DYCP-31DN Comb 13/6 wells (1.5mm)

    DYCP-31DN Comb 13/6 wells (1.5mm)

    Comb 13/6 wells (1.5mm)

    Cat. No.: 141-3141

    1.5mm thickness, with 13/6 wells, for use with DYCP-31DN system.

    The DYCP-31DN system is used to identify, isolate and prepare DNA and to measure molecular weight. It is made of high quality polycarbonate and is delicate and durable. When the user opens the lid it is powered off and the gel is easily viewed through the transparent jar. the DYCP-31DN system is available with different comb sizes. The different combs make this horizontal electrophoresis system ideal for any agarose gel application, including subsea electrophoresis for rapid electrophoresis of small amounts of sample, DNA, subsea electrophoresis for identification, isolation and preparation of DNA, and measurement of molecular weight.

  • DYCP-31DN Comb 25/11 wells (1.0mm)

    DYCP-31DN Comb 25/11 wells (1.0mm)

    Comb 25/11 wells (1.0mm)

    Cat. No.: 141-3143

    1.0mm thickness, with 25/11 wells, for use with DYCP-31DN system.

    DYCP-31DN system is used for identifying, separating, preparing DNA, and measuring the molecular weight. It is made of high quality polycarbonate that is exquisite and durable. It is easy to observe gel through the transparent tank.Its power source will be switched off when user opens the lid. DYCP-31DN system have different size of combs to use.The different combs make this horizontal electrophoresis system ideal for any agarose gel application including submarine electrophoresis, for rapid electrophoresis with small quantity samples, DNA , submarine electrophoresis, for identifying, separating and preparing DNA, and for measuring the molecular weight.

  • DYCP-31DN Comb 3/2 wells (2.0mm)

    DYCP-31DN Comb 3/2 wells (2.0mm)

    Comb 3/2 wells (2.0mm)

    Cat. No.: 141-3144

    1.0mm thickness, with 3/2 wells, for use with DYCP-31DN system.

  • DYCP-31DN Comb 13/6 wells (1.0mm)

    DYCP-31DN Comb 13/6 wells (1.0mm)

    Comb 13/6 wells (1.0mm)

    Cat. No.: 141-3145

    1.0mm thickness, with 13/6 wells, for use with DYCP-31DN system.

  • DYCP-31DN Comb 18/8 wells (1.0mm)

    DYCP-31DN Comb 18/8 wells (1.0mm)

    Comb 18/8 wells (1.0mm)

    Cat. No.: 141-3146

    1.0mm thickness, with 18/8 wells, for use with DYCP-31DN system.

    DYCP-31DN system is a horizontal gel electrophoresis system. It is for separation and identification of DNA and RNA fragments, PCR products. With external gel caster and gel tray, the gel making process is easier.The electrodes made of pure platinum with good conductive are easy to remove, simplifying cleaning. Its clear plastic construction for easy sample visualization.With different sizes of gel tray, DYCP-31DN can make four different sizes of gels. Different sizes of gels meet your different experiment requirements. It also has different types of comb for you use.

  • DYCP-31DN Electrode (Red)

    DYCP-31DN Electrode (Red)

    DYCP-31DN Electrode

    Replacement electrode (anode) for electrophoresis cell DYCP -31DN

    Electrode is made by pure platinum(the purity quotient of the noble metal ≥99.95%) which is electrolytic corrosion resistance and withstand high temperature.

    DYCP-31DN is used for identifying, separating, preparing DNA, and measuring the molecular weight. It is made of high quality polycarbonate that is exquisite and durable. It is easy to observe gel through the transparent tank.Its power source will be switched off when user opens the lid.This special lid design avoids making mistakes. The system equips removable electrodes that is easy to maintain and clean.Its black and fluorescent band on the gel tray makes it convenient to add the samples and observe the gel. With the different sizes of the gel tray, it can make four different sizes of gel.

  • DYCP-31DN Electrode (black)

    DYCP-31DN Electrode (black)

    DYCP-31DN Electrode

    Replacement electrode (cathode) for electrophoresis cell DYCP -31DN

    Electrode is made by pure platinum(the purity quotient of the noble metal ≥99.95%) which is electrolytic corrosion resistance and withstand high temperature.