Accessory
-
Microplate Reader WD-2102B
Microplate Reader (an ELISA analyzer or the product, instrument, analyzer) uses 8 vertical channels of optic road design, which can measure single or dual wavelength, absorbance and inhibition ratio, and carry out qualitative and quantitative analysis. This instrument uses 8-inch industrial-grade color LCD, touch screen operation and is connected externally to a thermal printer. The measurement results can be displayed in the whole board and can be stored and printed.
-
Superior Sample Loading Tool
Model: WD-9404(Cat. No.:130-0400)
This device is for loading sample for cellulose acetate electrophoresis(CAE),paper electrophoresis and other gel electrophoresis. It can load 10 samples at one time and improves your speed to load samples. This superior sample loading tool contains a locating plate, two sample plates and a fixed volume dispenser(Pipettor).
-
DYCZ-24DN Notched Glass Plate (1.0mm)
Notched glass plate (1.0mm)
Cat.No.:142-2445A
Notched glass plate sticked with spacer, the thickness is 1.0mm, for use with DYCZ-24DN system.
Vertical gel electrophoresis systems are primarily used for nucleic acid or protein sequencing. Achieve precise voltage control using this format that forces charged molecules to travel through the casted gel since it is the only buffer chamber connection. The low current used with the vertical gel systems does not require buffer to be recirculated. DYCZ – 24DN mini dual vertical electrophoresis cell utilizes protein and nucleic acid analytical tools for application within all aspects of life science research, ranging from purity determination to analysis protein.
-
DYCZ-24DN Special Wedge Device
Special Wedge Frame
Cat.No.:412-4404
This Special Wedge Frame is for DYCZ-24DN system. Two pieces of special wedge frames as a standard accessory packed in our system.
DYCZ – 24DN is a mini dual vertical electrophoresis applicable for SDS-PAGE and native-PAGE. This special wedge frame can firmly fix the gel room and avoid leakage.
A vertical gel method is slightly more complex than its horizontal counterpart. A vertical system utilizes a discontinuous buffer system, where the top chamber contains the cathode and the bottom chamber contains the anode. A thin gel (less than 2 mm) is poured between two glass plates and mounted so that the bottom of the gel is submerged in buffer in one chamber and the top is submerged in buffer in another chamber. When current is applied, a small amount of buffer migrates through the gel from the top chamber to the bottom chamber.
-
DYCZ-24DN Gel Casting Device
Gel Casting Device
Cat.No.:412-4406
This Gel Casting Device is for DYCZ-24DN system.
Gel electrophoresis can be conducted in either a horizontal or vertical orientation. Vertical gels are generally composed of an acrylamide matrix. Pore sizes of these gels depend on the concentration of chemical components: agarose gel pores (100 to 500 nm diameter) are larger and less uniform compared to that of acrylamide gelpores (10 to 200 nm in diameter). Comparatively, DNA and RNA molecules are larger than a linear strand of protein, which are often denatured prior to, or during this process, making them easier to analyze. Thus, proteins are run on acrylamide gels (vertically).DYCZ – 24DN is a mini dual vertical electrophoresis applicable for SDS-PAGE and native-PAGE. It has the function of casting gels in original position with our special designed gel casting device.
-
DYCP-31DN Gel Casting Device
Gel Casting Device
Cat. No.: 143-3146
This gel casting device is for DYCP-31DN system.
Gel electrophoresis can be conducted in either a horizontal or vertical orientation. Horizontal gels are typically composed of an agarose matrix. Pore sizes of these gels depend on the concentration of chemical components: agarose gel pores (100 to 500 nm diameter) are larger and less uniform compared to that of acrylamide gelpores (10 to 200 nm in diameter). Comparatively, DNA and RNA molecules are larger than a linear strand of protein, which are often denatured prior to, or during this process, making them easier to analyze. Thus, DNA and RNA molecules are more often run on agarose gels (horizontally).Our DYCP-31DN system is a horizontal electrophoresis system. This molded gel casting device can make 4 different sizes of gels by different gel trays.
-
DYCZ-40D Electrode Assembly
Cat.No.: 121-4041
The electrode assembly is matched with DYCZ-24DN or DYCZ-40D tank. Used to transfer the protein molecule from the gel to membrane like nitrocellulose membrane in the Western Blot experiment.
Electrode assembly is the important part of DYCZ-40D,which has the capacity to hold two gel holder cassettes for electrophoresis transfer between the parallel electrodes only 4.5 cm apart. The driving force for blotting applications is the voltage applied over the distance between the electrodes. This short 4.5 cm electrode distance allows generation of higher driving forces to produce efficient protein transfers. Other features of DYCZ-40D includes latches on the gel holder cassettes for easy handling purpose, supporting body for transfer (electrode assembly) comprise of red and black color parts and red and black electrodes to ensure proper orientation of the gel during the transfer, and an efficient design which simplifies insertion and removal of the gel holder cassettes from the supporting body for transfer (electrode assembly).
-
DYCZ-24DN Glass Plate (2.0mm)
Glass plate (2.0mm)
Cat.No.:142-2443A
Glass plate with 2.0mm thickness, for use with DYCZ-24DN system.
DYCZ – 24DN mini dual vertical electrophoresis cell is for rapid analysis of protein and nucleic acid samples in miniature polyacrylamide and agarose gels. DYCZ – 24DN system make casting and running slab gels almost effortless. Only several simple steps can finish assembling the gel rooms. And the special wedge frame can fix the gel rooms in the casting stand firmly. And after you put the gel casting stand in the gel casting device and screw the two handles to the right position, you can cast the gel without any worry about the leakage at all. The sign printed on the handles or the alarm sound when you screw the handle will help you a lot. Please make sure that glass plate is clean and dry before proceeding.
-
DYCP-31DN Comb 13/6 wells (1.5mm)
Comb 13/6 wells (1.5mm)
Cat. No.: 141-3141
1.5mm thickness, with 13/6 wells, for use with DYCP-31DN system.
The DYCP-31DN system is used to identify, isolate and prepare DNA and to measure molecular weight. It is made of high quality polycarbonate and is delicate and durable. When the user opens the lid it is powered off and the gel is easily viewed through the transparent jar. the DYCP-31DN system is available with different comb sizes. The different combs make this horizontal electrophoresis system ideal for any agarose gel application, including subsea electrophoresis for rapid electrophoresis of small amounts of sample, DNA, subsea electrophoresis for identification, isolation and preparation of DNA, and measurement of molecular weight.
-
DYCZ-24DN Notched Glass Plate (1.5mm)
Notched glass plate (1.5mm)
Cat.No.:142-2446A
Notched glass plate sticked with spacer, the thickness is 1.5 mm, for use with DYCZ-24DN system.
-
DYCP-31DN Comb 25/11 wells (1.0mm)
Comb 25/11 wells (1.0mm)
Cat. No.: 141-3143
1.0mm thickness, with 25/11 wells, for use with DYCP-31DN system.
DYCP-31DN system is used for identifying, separating, preparing DNA, and measuring the molecular weight. It is made of high quality polycarbonate that is exquisite and durable. It is easy to observe gel through the transparent tank.Its power source will be switched off when user opens the lid. DYCP-31DN system have different size of combs to use.The different combs make this horizontal electrophoresis system ideal for any agarose gel application including submarine electrophoresis, for rapid electrophoresis with small quantity samples, DNA , submarine electrophoresis, for identifying, separating and preparing DNA, and for measuring the molecular weight.
-
DYCP-31DN Comb 3/2 wells (2.0mm)
Comb 3/2 wells (2.0mm)
Cat. No.: 141-3144
1.0mm thickness, with 3/2 wells, for use with DYCP-31DN system.